Alternating Currents and Transformers
SPEC 3.7.5.5 & 3.7.5.6
RMS values, oscilloscopes, transformer equations, and power transmission
Alternating Current (AC)
Definition
Alternating current (AC) is an electric current that periodically reverses direction, in contrast to direct current (DC) which flows in only one direction.
When a coil rotates in a magnetic field, an EMF is induced. From Lesson 7.06, this EMF follows:
Why AC is Sinusoidal
Because the equation contains sin(ωt), the induced EMF is alternating - it changes direction with time (shown by the changing sign).
UK Mains Supply
In the UK, mains electricity is supplied as AC at 230 V (RMS) and 50 Hz. This means the current reverses direction 50 times per second.
Sinusoidal AC Waveform
AC voltage and current vary sinusoidally with time. The diagram shows the four key measurements:
PointMeasurementDescription
①Peak Voltage (V₀ or V̂)Maximum amplitude from equilibrium (zero line)
②Time Period (T)Time for one complete cycle; frequency f = 1/T
③RMS Voltage (V_rms)= V₀/√2 ≈ 0.707 × V₀ (effective DC equivalent)
④Peak-to-Peak (V_p-p)= 2V₀ (total amplitude from min to max)
Root Mean Square (RMS) Values
Definition
The RMS value of an alternating current or voltage is the equivalent DC value that would produce the same power dissipation in a resistor. It is the average of all the squares of the possible voltages, giving the average value of voltage output by the supply (in either direction).
Why do we need RMS? The average value of a sinusoidal AC signal is zero (equal positive and negative halves). But power is proportional to V² or I², which is always positive.
Key Formulas
Where V₀ and I₀ are the peak values of voltage and current.
Important
When mains voltage is quoted as "230 V", this is the RMS value. The actual voltage oscillates between +325 V and -325 V!
01Worked Example - Peak to RMS
An AC power supply has a peak voltage of 12.0 V. Calculate:
(a) the RMS voltage
(b) the peak-to-peak voltage
a)
Using
•
b)
Peak-to-peak voltage = 2 × V₀
•
02Worked Example - UK Mains
UK mains electricity is supplied at 230 V RMS and 50 Hz. Calculate:
(a) the peak voltage
(b) the peak-to-peak voltage
(c) the time period of the AC supply
a)
Rearranging gives
•
(to 2 s.f.: 330 V)
b)
c)
(or 20 ms)
Using an Oscilloscope
An oscilloscope displays how voltage varies with time. You can adjust the scale of both axes to make measurements easier:
Y-Gain Control
Volts per division on the vertical (Y) axis. Controls the height of the trace.
Time Base Control
Time per division on the horizontal (X) axis. Controls how "stretched" the waveform appears.
Taking measurements: Count the number of divisions and multiply by the setting:
Peak voltage: Divisions from centre to peak × Y-gain (V/div)
Time period: Divisions for one cycle × Time base (s/div)
Frequency: f = 1/T
Oscilloscope Traces: DC vs AC
The oscilloscope can display different signals. The time-base can be turned on or off. With time-base off, the trace shows all the possible voltages at any time in one area:
Straight line parallel to axis at output voltage level
Single dot at the output voltage level
Sinusoidal waveform showing voltage vs time
Vertical line showing all possible voltages
Why Turn Time Base Off?
With time base off, the trace shows all the possible voltages at any time in one area. This is useful for measuring the voltage range without needing to read a moving trace. For AC, the vertical line length = peak-to-peak voltage.
03Worked Example - Oscilloscope Reading
An oscilloscope displays an AC waveform. The Y-gain is set to 2.0 V per division and the time base is 5.0 ms per division. The trace shows a peak height of 3.5 divisions and one complete cycle takes 4 divisions.
Calculate: (a) the peak voltage (b) the RMS voltage (c) the frequency
a)
Peak voltage = divisions × Y-gain = 3.5 × 2.0 = 7.0 V
b)
c)
Period T = divisions × time base = 4 × 5.0 ms = 20 ms = 0.020 s
•
Transformer Principles
Definition
A transformer is used with alternating currents to change the size of their voltage. It consists of a primary coil (attached to input), secondary coil (connected to output), and an iron core.
How It Works
The primary coil provides a changing magnetic field (because AC changes direction). This passes through the iron core and interacts with the secondary coil, inducing a voltage in the secondary (by Faraday's law).
Transformer Equations
By using Faraday's law, we can show that the ratio of voltages equals the ratio of turns:
Transformer Equation
Nₛ = secondary turns, Nₚ = primary turns
Vₛ = secondary voltage, Vₚ = primary voltage
Step-Up Transformer
Nₛ > Nₚ (more turns on secondary)
Vₛ > Vₚ (voltage increases)
Iₛ < Iₚ (current decreases)
Used at power stations
Step-Down Transformer
Nₛ < Nₚ (fewer turns on secondary)
Vₛ < Vₚ (voltage decreases)
Iₛ > Iₚ (current increases)
Used for consumers
Ideal Transformer (100% Efficient)
Power in = Power out (no energy losses)
Important
Transformers only work with AC! DC produces a constant flux, so no EMF is induced in the secondary.
04Worked Example - Transformer Turns Ratio
A step-down transformer has 2400 turns on the primary coil and is connected to the 230 V mains. The secondary coil has 120 turns.
Calculate: (a) the secondary voltage (b) the current in the primary if the secondary current is 3.0 A (assume ideal transformer)
a)
Using , rearrange for Vₛ:
•
b)
For ideal transformer: IₚVₚ = IₛVₛ
•
Check: Step-down gives lower voltage but higher current. Vₛ < Vₚ ✓, Iₛ > Iₚ ✓
Worked Example - Step-Up Transformer Design05
A transformer is required to step up the 230 V RMS mains supply to 5.0 kV RMS for a neon sign. The secondary coil has 900 turns. How many turns are needed on the primary coil?
1
Convert secondary voltage: Vₛ = 5.0 kV = 5000 V
2
Using , rearrange for Nₚ:
•
•
Check: For step-up, Nₛ > Nₚ. Indeed, 900 > 41 ✓
Transformer Efficiency
Real transformers are not 100% efficient. The efficiency can be found using:
Efficiency Formula
One of the main causes of energy loss is the production of eddy currents:
Eddy Currents and Lenz's Law
Eddy currents are induced by the alternating magnetic field in the primary coil, and form loops in the iron core. Due to Lenz's law, they oppose the field that produced them, reducing the field's flux density. They also generate heat, which causes energy to be lost.
How Laminations Reduce Losses
The core is made of layers of iron separated by insulator. The eddy currents cannot pass through the insulator, so their amplitude is reduced. This significantly decreases the I²R heating losses. Eddy currents can also be reduced by using a high resistivity core material.
Causes of Transformer Inefficiency
Energy LossCauseHow to Reduce
Eddy CurrentsChanging flux induces current loops in iron core → I²R heatingLaminated core (layers separated by insulator) or high resistivity core material
Resistance HeatingCurrent through coil windings causes I²R lossesUse thick wire with low resistance
HysteresisEnergy needed to magnetise/demagnetise core each cycle (if core is not easily magnetised)Use soft iron core - easy magnetisation and demagnetisation
Flux LeakageNot all flux from primary links to secondaryWind coils close together; good core design
Typical Efficiency
Large power transformers can be over 99% efficient. The main losses are eddy currents (reduced by laminations) and resistance heating in the coils.
Worked Example - Transformer Efficiency06
A transformer has a primary coil connected to a 230 V supply and draws a current of 0.80 A. The secondary coil provides 160 W of power. Calculate the efficiency of the transformer.
1
Calculate input power: Pᵢₙ = IₚVₚ = 0.80 × 230 = 184 W
2
Output power is given: Pₒᵤₜ = 160 W
3
Calculate efficiency:
•
Energy lost: 184 - 160 = 24 W (lost as heat in core and windings)
High Voltage Power Transmission
When transferring electrical power, the power lost due to resistance is equal to I²R. Therefore it is vital to reduce the current to a minimum value to prevent unnecessary energy losses.
The Key Principle
As power = current × voltage, when the voltage is stepped up, the current will decrease (for the same power). This dramatically reduces I²R losses in the transmission cables.
Key Calculation
If voltage is increased by factor of 10, current decreases by factor of 10.
Power loss = I²R decreases by factor of 100!
This is why we use very high voltages (~400 kV in UK) for transmission.
07Worked Example - Power Transmission
Alternating current leaves a power station at 25 kV and enters a step-up transformer with 50 turns on its primary coil and 750 turns on its secondary coil.
(a) Find the output voltage of the transformer.
(b) 500 MW of power is transmitted along 225 km of wire with resistance 0.2 Ω per km. Find the power wasted.
a)
Using , so
•
(or 3.75 × 10⁵ V)
b)
Total resistance = 225 × 0.2 = 45 Ω
•
Find current: I = P/V = (500 × 10⁶)/(3.75 × 10⁵) = 1333 A (to 3 s.f.)
•
Power wasted = I²R = (1333)² × 45 = 8 × 10⁷ W (80 MW)
Practice
Question 1:
(a) the RMS voltage
(b) the time period
(c) the peak-to-peak voltage
(a) V_rms = V₀/√2 = 18/1.414 = 12.7 V
(b) T = 1/f = 1/60 = 0.0167 s (16.7 ms)
(c) V_p-p = 2V₀ = 2 × 18 = 36 V
Practice
Question 2:
(a) the secondary voltage
(b) the power output
(c) the current in the primary coil
(a) V_s = V_p × (N_s/N_p) = 12 × (3000/500) = 12 × 6 = 72 V
(b) P_out = I_sV_s = 0.25 × 72 = 18 W
(c) η = P_out/Pᵢₙ, so Pᵢₙ = P_out/η = 18/0.92 = 19.6 W
I_p = Pᵢₙ/V_p = 19.6/12 = 1.63 A
Practice
Question 3:
(a) the peak voltage
(b) the RMS voltage
(c) the frequency of the AC supply
(a) V₀ = 2.4 div × 5 V/div = 12 V
(b) V_rms = V₀/√2 = 12/1.414 = 8.5 V
(c) T = 8 div × 2 ms/div = 16 ms = 0.016 s
f = 1/T = 1/0.016 = 62.5 Hz
Summary
Key Formulas
QuantityFormula
RMS Voltage
RMS Current
Frequency
Transformer Ratio
Ideal Transformer
Efficiency
Power Loss
Key Exam Skills
Convert between peak, peak-to-peak, and RMS values
Read voltage, period, and frequency from oscilloscope traces
Sketch oscilloscope traces for DC/AC with time-base on/off
Apply transformer equations and calculate efficiency
Explain why high voltage is used for power transmission (reduces I²R losses)
Describe causes of transformer inefficiency and how to reduce them
Next: Alternating Current (AC)